Case study 12 - ST2000DM001 - "SNOOOZZZZZZEEE Retry"



 


F3 7>




Boot 0x40M
 Spin Up
 Trans.

Tech Unlock Handshake: 0x2038B66B
Reply:

 Spin Up
SpinOK
TCC:0022

 SNOOOZZZZZZEEE Retry
 EDAC Value = 0000F018E59FE12A
 SNOOOZZZZZZEEE Retry
 EDAC Value = 0000F018E59FE12A
No HOST FIS-ReadyStatusFlags 0002A1A1
ASCII Diag mode

F3 T>
F3 T>

 1. This model of Seagate Grenada was one of the earlier models where terminal access to the SA was locked down.
2. The underlying issue, after getting terminal access was resolved by disabling media cache and clearing the glist


3 NEW PCB ONE CHECK





A year after the fact, we finally now have a solution and were able to fully recover this client's data.